Industrial Air Monitor Featuring Sports Venue Optimized Detection Profiles and Rapid Response Sensors for Air Management
Product Description:
The MR-A Portable Air Quality Monitor is a sports facility management solution engineered for maintaining optimal air quality in stadiums, arenas, and recreational facilities. This specialized handheld monitoring device provides comprehensive detection of sports venue-related airborne hazards including crowd-generated CO2 levels, concession stand cooking emissions, cleaning chemical vapors, and particulate matter from high-traffic activities. The system features sports-optimized detection profiles with specialized sensors for monitoring indoor air quality during events, training sessions, and facility maintenance operations.
Its rapid response capabilities enable immediate detection of hazardous conditions during crowded events, while its extended battery life supports continuous monitoring throughout extended sporting events and tournaments. The device's wireless data transmission enables integration with facility management systems for real-time air quality surveillance across multiple venue sections, ensuring athlete and spectator safety during various sporting activities and events.![]()
Features:
· Sports venue-optimized detection profiles for athletic facilities
· Crowd CO2 monitoring for ventilation control
· Concession stand emission tracking
· High-traffic area particulate monitoring
· Rapid response for event safety
· Extended battery operation for full event coverage
· Wireless integration with facility management systems
· Real-time air quality display for venue managers
· Data logging for event safety documentation
· Backlit display for indoor arena operation
· Multiple alarm configurations for spectator safety
· Rugged construction for venue durability
Technical Parameters:
| Parameter | Measurement Range | Resolution | Accuracy | Detection Method |
| CO2 | 0-10000 ppm | 10 ppm | ±3% | NDIR |
| PM2.5 | 0-1000 μg/m³ | 1 μg/m³ | ±10% | Laser scattering |
| PM10 | 0-2000 μg/m³ | 1 μg/m³ | ±10% | Laser scattering |
| VOC | 0-200 ppm | 1 ppm | ±5% | PID |
| CO | 0-100 ppm | 0.1 ppm | ±3% | Electrochemical |
| NO2 | 0-50 ppm | 0.1 ppm | ±3% | Electrochemical |
| Temperature | +10°C to +40°C | 0.1°C | ±0.5°C | RTD |
| Humidity | 20-80% RH | 0.5% RH | ±3% RH | Capacitive |
| Battery Life | 16+ hours | - | - | Lithium-ion |
| Operating Temperature | +5°C to +45°C | - | - | - |
Applications:
· Indoor arena air quality monitoring
· Stadium ventilation system optimization
· Concession stand emission surveillance
· Training facility atmospheric assessment
· Event safety air quality verification
· Athlete exposure monitoring
· Spectator comfort air quality management
· Sports facility maintenance operations
· Event emergency response planning
· Venue health and safety compliance