Portable gas calibration equipment designed to meet medical device regulations supporting assurance and regulatory documentation requirements
Product Description:
MR-DF3 portable high-precision dynamic gas distribution meter designed for medical and healthcare applications provides specialized gas calibration capabilities essential for medical facilities, respiratory therapy equipment, and biomedical research laboratories. This precision portable instrument is engineered to meet the stringent requirements of medical gas standards, ensuring accurate calibration of oxygen concentrators, ventilators, anesthesia machines, and respiratory monitoring devices. The system features medical-grade construction with biocompatible materials and enhanced cleanliness standards suitable for healthcare environments.
The MR-DF3 medical variant incorporates specialized calibration profiles for medical gases including oxygen, carbon dioxide, nitrous oxide, helium, and various respiratory therapy gas mixtures, with exceptional accuracy critical for patient safety and treatment efficacy. Its portable design allows for flexible use within medical facilities, enabling biomedical engineers and technicians to move the instrument between different departments and equipment locations, while the comprehensive data logging capabilities support medical device quality assurance and regulatory documentation requirements.![]()
Features:
· Medical-grade construction with biocompatible materials
· Specialized calibration profiles for medical gases
· Compliance with medical device regulations (FDA, CE, ISO)
· Enhanced cleanliness standards for healthcare environments
· Portable design for flexible medical facility use
· Automated calibration scheduling for medical devices
· Comprehensive data logging for regulatory compliance
· Multi-user access with audit trail capabilities
· Support for respiratory therapy gas mixtures
· Anesthesia machine calibration support
· Ventilator performance verification
· Medical research laboratory gas standard generation
Technical Parameters:
| Parameter | Specification |
| Mass Flow Controller Range | Can be selected according to user needs |
| Flow Accuracy | <1%F.S |
| Flow Linearity | ±0.3%F.S |
| Flow Repeatability | ±0.2%F.S |
| Turndown Ratio | 100:1 (Can be customized as required) |
| Maximum Ratio | 1000:1 (Can be customized according to needs) |
| Input Pressure | 100Kpa~500Kpa (Can be customized according to user needs) |
| Operating Temperature | -10℃~+50℃ |
| Operating Humidity | <80%RH (No condensation) |
| Battery Life | >20 hours continuous operation |
| Weight | <8kg (portable) |
Applications:
· Hospital medical gas system calibration
· Respiratory therapy equipment verification
· Ventilator performance testing and calibration
· Anesthesia machine gas mixture calibration
· Oxygen concentrator accuracy verification
· Hyperbaric chamber gas monitoring support
· Medical research laboratory gas standard generation
· Rehabilitation center respiratory equipment calibration
· Emergency medical services equipment verification
· Medical device manufacturing quality control
· Clinical research study gas mixture preparation
· Medical gas regulatory compliance testing