Home > Products >
Gas Detector Instrument
>
GCF-M10 Gas Alarm Control Cabinet - Dual-Power Redundancy Keeps 112 Detectors Alive Through a Blackout

GCF-M10 Gas Alarm Control Cabinet - Dual-Power Redundancy Keeps 112 Detectors Alive Through a Blackout

Product Details:
Place of Origin: CHINA
Brand Name: CSSC
Certification: CCS, BV, LR, SIL3
Detail Information
Place of Origin:
CHINA
Brand Name:
CSSC
Certification:
CCS, BV, LR, SIL3
Highlight:

High Light

Highlight:

Gas Alarm Control Cabinet dual-power redundancy

,

Gas Alarm Control Cabinet 112 detectors

,

Gas Detector Instrument with blackout protection

Trading Information
Minimum Order Quantity:
10 sets
Delivery Time:
5-8 work days
Supply Ability:
1000 sets/month
Product Description
GCF-M10 Gas Alarm Control Cabinet
Dual-power redundancy ensures continuous operation of 112 detectors during power outages, maintaining critical gas monitoring when it matters most.
Critical Power Redundancy
Dual power supply with independent backup keeps all 112 detectors operational for 30 minutes after main power loss - the critical window when alarms are most vital.
Technical Operation
  • Acquisition: 112 channels of 3-wire 4-20 mA signals with sampling period under 8 ms
  • Indication: Large LCD display with LED indicators showing live concentration and alarm status by zone
  • Action: 16 relay outputs (AC 220 V / 3 A) and 4 controllable 220 V / 5 A power outputs
  • Communication: RJ45 Modbus TCP/IP, RS485 Modbus RTU, and OPC UA for system integration
  • Fault Management: Proprietary software anti-interference technology with soft fault detection
Power Architecture
Dual independent power supplies with dual-switch arrangement provide complete redundancy. Backup power maintains all 112 detectors for 30 minutes post-power loss. Rapid 8 ms sampling ensures full channel population scanning faster than detector state changes, with threshold breach response within 5 seconds.
Performance Features
  • Dual power supply redundancy with independent backup
  • Sampling period under 8 ms for rapid response
  • All-new cabinet design - anti-corrosion and anti-vibration
  • Zoned monitoring with touch screen support and OPC UA protocol
  • Cascade design supporting 112 input channels and 32 output channels
  • Main/backup power design with dual-switch redundancy
Interfaces & System Integration
Supports up to 3 seven-inch display screens. Output interfaces include 16 relay channels (AC 220 V / 3 A), 4 controllable 220 V / 5 A power outputs, RJ45 Modbus TCP/IP, RS485 Modbus RTU, and OPC UA for connection to PLC, DCS, and fire-protection systems.
Typical Applications
  • LNG carriers and LNG-fuelled vessels
  • Bulk carriers, oil tankers and chemical tankers
  • Offshore platforms and FPSOs
  • Naval and coast-guard vessels
  • Shipyards and new-build sea trials
  • Any vessel or offshore installation requiring centralized gas monitoring with fire-protection linkage
Certifications & Approvals
CCS Type Approval Certificate, BV Type Approval Certificate (Certificate No. 81499/A0 BV), LR Type Approval Certificate, SIL3 Functional Safety Certification, and CCS Cyber Security Certificate.
Global Service Network
Service centers located in China, Germany, Panama, Cyprus, UAE, Northern Europe, UK, Ireland, Singapore, and Taiwan, providing rapid on-site support to shipyards and ship-owners worldwide.